Galvanized Steel Perforated Square Tube​

Galvanized Steel Perforated Square Tube​

Galvanized Steel Perforated Square Tube features pre-punched holes that allow bolts and fasteners to be positioned without additional on-site drilling. Hole diameter, spacing, and arrangement can be specified to match different assembly requirements. It is particularly useful for adjustable support systems, equipment mounting, and structures requiring repeated mechanical connections.

  • Check Mark Mill Test Certificate Provided
  • Check Mark Strict Quality Inspection
  • Check Mark Custom Sizes Available
  • Check Mark On-Time Global Delivery

Galvanized Steel Perforated Square Tube can be manufactured with elongated slots along one or more faces. The metal between adjacent openings forms narrow sections of the tube wall, making slot position and spacing relevant to the finished component. Where the tube serves a structural purpose, the effect of these openings must be considered rather than relying on the properties of an unperforated section.

The appearance of the slots depends partly on the punching method and tooling used. Wall thickness, slot dimensions, and the number of openings influence how the tube is processed. On thin-walled sections, excessive punching force or inadequate support can cause local distortion, so the production method needs to suit the selected tube specification.

For galvanized steel pipe orders involving perforated sections, drawings should identify the punched face, slot dimensions, and distance from the tube ends. A dimensioned drawing is especially useful when openings on different faces must align or when several components are assembled together. This helps avoid discrepancies between the supplied tubes and the intended connection layout.

Product Features

  • Flat Exterior Faces: The square profile provides four flat outer surfaces, allowing the tube to sit against flat plates, panels, or other structural components without requiring a curved contact surface.
  • Defined Slot Edges: Elongated openings have rounded ends rather than sharp rectangular corners, providing a distinct slot geometry for applications that specify this opening shape.
  • Galvanized Surface Protection: The zinc coating helps protect covered steel surfaces against atmospheric corrosion. Protection at punched edges depends on whether perforation takes place before or after galvanizing.
  • Open-Ended Hollow Profile: The tube has a continuous internal cavity accessible from its ends, allowing the interior to be inspected or accommodated in fabrication arrangements where end access is needed.

Technical Specifications

ParameterSpecification
Cross SectionSquare Hollow Section
Tube Size25×25 / 30×30 / 40×40 / 50×50 / 60×60 / 80×80 mm
Wall Thickness1.5 / 2.0 / 2.5 / 3.0 mm
Steel GradeQ235B / Q355B
Hole ShapeOblong Slots (Rounded Ends)
Slot Size (L × W)20×8 / 25×10 / 30×10 / 40×12 mm
Slot Pitch (C/C)40 / 50 / 60 / 80 mm
Perforated Faces1 / 2 / 4 Faces
Tube Length3000 / 6000 mm
Surface FinishGalvanized
PackingSteel-Strapped Bundles

Typical Size Combinations

Tube Size (mm)Thickness (mm)Slot Size (mm)Slot Pitch (mm)
25×251.520×840
30×301.525×1050
40×402.030×1060
50×502.040×1280
60×602.540×1280
80×803.040×1280

Note: Dimensions shown are illustrative reference combinations, not verified production specifications. Actual availability, slot arrangements and galvanizing requirements must be confirmed before ordering.
</p >

Applications

Galvanized Steel Perforated Square Tube is used in fabricated assemblies where slotted openings support adjustable connections and modular construction. Typical applications include:

Galvanized Steel Perforated Square Tube applications in storage racking, solar panel frames, machinery supports and modular fencing

  • Adjustable Storage Racking: Used in storage frames and rack components where slotted connections allow shelves, brackets and supporting members to be repositioned. Load capacity depends on the complete rack design.
  • Solar Panel Support Frames: Suitable for selected mounting brackets and secondary support members in solar installations, provided the tube dimensions, perforations and corrosion protection meet project requirements.
  • Machinery Support Structures: Applied in equipment frames, auxiliary supports and removable mounting assemblies where mechanical connections are needed for installation and maintenance.
  • Modular Fencing Systems: Incorporated into detachable fence frames and enclosure assemblies, allowing panels and connecting components to be assembled or replaced according to the fence design.

Frequently Asked Questions

1. How does perforation affect the strength of a square steel tube?

Slots reduce the amount of steel in the tube wall and can create stress concentrations around their edges. The effect is not limited to the total area removed; slot orientation, spacing, and proximity to connections also matter. For load-bearing applications, an unperforated square tube of the same size should not be treated as having identical structural capacity.

2. Is it better to punch the slots before or after galvanizing?

For applications requiring zinc protection around the slot edges, punching before hot-dip galvanizing is generally preferable, provided the finished coating meets the required specification. Punching pre-galvanized tubing afterward exposes steel along the cut edges. These areas may need suitable repair or additional protection, depending on the service environment.

3. How should slot dimensions and positional tolerances be specified?

Use a dimensioned drawing that identifies the slot length, width, center-to-center pitch, and distance from a defined tube end. If several slots must align with mating parts, indicate the positional tolerance relative to a common reference. The manufacturer should confirm the achievable tolerances before the drawing is approved for production.

4. Can the tubes be cut without damaging the slots?

Yes, with an appropriate cutting method and sufficient clearance between the cut line and nearby openings. Cutting too close to a slot may leave a weakened or irregular end section. For finished components, specify the overall length, end-to-slot distance, and whether burr removal or cut-edge protection is required.

5. What should be considered when using these tubes outdoors?

The exposure environment matters as much as the initial appearance of the zinc coating. Salt-laden air, industrial pollution, and water trapped inside hollow sections can increase corrosion risk. Suitable drainage, coating specifications, and protection of exposed steel should be addressed during the design stage.

6. What information helps avoid mistakes when ordering perforated square tubes?

The most useful document is a drawing showing the tube cross-section, perforated faces, slot orientation, and the location of the first slot. Include the material grade, coating requirement, finished length, and order quantity. If the parts must fit an existing assembly, supplying a mating-part drawing or sample can help prevent alignment problems.